Sign in
Author
|
Conference
|
Journal
|
Organization
|
Year
|
DOI
Look for results that meet for the following criteria:
since
equal to
before
between
and
Search in all fields of study
Limit my searches in the following fields of study
Agriculture Science
Arts & Humanities
Biology
Chemistry
Computer Science
Economics & Business
Engineering
Environmental Sciences
Geosciences
Material Science
Mathematics
Medicine
Physics
Social Science
Multidisciplinary
Keywords
(4)
Common Sense
Experimental Tests
Measurement System
Personal Digital Assistant
Subscribe
Academic
Publications
IMPROVED SYNCHRONIZING PROCEDURE OF PDAS TO DELIVERY THE COMMON SENSE OF THE TIME TO STAND ALONE MEASUREMENT INSTRUMENT
IMPROVED SYNCHRONIZING PROCEDURE OF PDAS TO DELIVERY THE COMMON SENSE OF THE TIME TO STAND ALONE MEASUREMENT INSTRUMENT,Domenico Luca Carnì,Domenico G
Edit
IMPROVED SYNCHRONIZING PROCEDURE OF PDAS TO DELIVERY THE COMMON SENSE OF THE TIME TO STAND ALONE MEASUREMENT INSTRUMENT
(
Citations: 2
)
BibTex
|
RIS
|
RefWorks
Download
Domenico Luca Carnì
,
Domenico Grimaldi
,
Francesco Lamonaca
The paper proposes the optimized evolution of the previous procedure to synchronize the PDAs to the node of the Distributed
Measurement System
(DMS) in order to physically bring the
common sense
of time to the stand alone node. The improvements concern with (i) the selection of the clock node as reference one, (ii) the contemporaneous synchronization of all the involved PDAs, and (iii) the compensation of the effects of the drift of the electronic components on the number of system cycle after whom the control of the MI must be executed. The improvements pointed out originate from the practical evaluation of the performance of the previous synchronization procedure. The improved procedure meets the advantages of the synchronization based on the IEEE std 1588.
Experimental tests
are shown to validate the synchronization procedure and to highlight the advantages.
Cumulative
Annual
View Publication
The following links allow you to view full publications. These links are maintained by other sources not affiliated with Microsoft Academic Search.
(
www.imeko2009.it.pt
)
Citation Context
(2)
...The solution proposed in [
5
] regards with the synchronization of the PDA to the common reference clock of DMS, before to bring “physically” the clock reference time to the MI. In particular, the Master PC is previously synchronized by the standard IEEE 1588 [6] to the boundary clock of the DMS...
...Characteristic aspect of this procedure is that the system’s cycles of the PDA [7] is used in the place of the system time and the timestamp mechanism [
5
], because they introduce time delay multiple of the ms [5]...
...Characteristic aspect of this procedure is that the system’s cycles of the PDA [7] is used in the place of the system time and the timestamp mechanism [5], because they introduce time delay multiple of the ms [
5
]...
...The synchronization is performed between the two ESHs, according to [10], and, in separately modality, between the two PDAs according to [
5
]...
...PDA synchronized according to the procedure presented in [
5
], based on the lookup table, and the XHI pointed out...
...In particular, curve (a) refers to the trend of the mean value of the delay obtained with the first technique [
5
] and the curve (b) is the trend of the standard deviation...
Domenico Grimaldi
,
et al.
Synchronization of stand alone measurement instruments by PDA and embe...
...Fig.2 shows the block scheme of the hardware connections and the block diagram of the performed operations in (i) the First Phase in which the synchronization is performed between two HIs, Fig.2 a) and b), and (ii) the Second Phase in which the HIs are employed to synchronize two stand alone MIs [
10
], Fig.2 c) and d)...
Domenico Grimaldi
,
et al.
Reduction of the random variation of time delay to synchronize Measure...
References
(3)
Clock synchronization for wireless sensor networks: a survey
(
Citations: 243
)
Bharath Sundararaman
,
Ugo Buy
,
Ajay D. Kshemkalyani
Journal:
Ad Hoc Networks
, vol. 3, no. 3, pp. 281-323, 2005
Improving reliability of IEEE1588 in electric substation automation
(
Citations: 8
)
Jean-Charles Tournier
,
Xiao Yin
Conference:
IEEE International Symposium on Precision Clock Synchronization for Measurement, Control and Communication - ISPCS
, 2008
Delivery the common sense of the time to stand alone Measurement Instrument by PDA
(
Citations: 4
)
Antonino Barresi
,
Domenico Grimaldi
,
Francesco Lamonaca
Conference:
IEEE Instrumentation and Measurement Technology Conference - I2MTC
, pp. 1341-1345, 2009
Sort by:
Citations
(2)
Synchronization of stand alone measurement instruments by PDA and embedded hardware
Domenico Grimaldi
,
Francesco Lamonaca
,
Alfonso Nastro
Conference:
IEEE Instrumentation and Measurement Technology Conference - I2MTC
, pp. 1-5, 2011
Reduction of the random variation of time delay to synchronize Measurement Instruments
(
Citations: 1
)
Domenico Grimaldi
,
Francesco Lamonaca
Conference:
IEEE Instrumentation and Measurement Technology Conference - I2MTC
, pp. 1561-1566, 2010