Academic
Publications
A high-sensitivity laser-pumped M x magnetometer

A high-sensitivity laser-pumped M x magnetometer,10.1140/epjd/e2006-00037-y,European Physical Journal D,S. Groeger,G. Bison,J.-L. Schenker,R. Wynands,

A high-sensitivity laser-pumped M x magnetometer   (Citations: 14)
BibTex | RIS | RefWorks Download
.   We discuss the design and performance of a laser-pumped cesium vapor magnetometer in the Mx configuration. The device will be employed in the control and stabilization of fluctuating magnetic fields and gradients in a new experiment searching for a permanent electric dipole moment of the neutron. We have determined the intrinsic sensitivity of the device to be 15 fT in a 1 Hz bandwidth, limited by technical laser noise. In the shot noise limit the magnetometer can reach a sensitivity of 10 fT in a 1 Hz bandwidth. We have used the device to study the fluctuations of a stable magnetic field in a multi-layer magnetic shield for integration times in the range of 2–100 seconds. The residual fluctuations for times up to a few minutes are traced back to the instability of the power supply used to generate the field.
Journal: European Physical Journal D - EUR PHYS J D , vol. 38, no. 2, pp. 239-247, 2006