Sign in
Author
|
Conference
|
Journal
|
Organization
|
Year
|
DOI
Look for results that meet for the following criteria:
since
equal to
before
between
and
Search in all fields of study
Limit my searches in the following fields of study
Agriculture Science
Arts & Humanities
Biology
Chemistry
Computer Science
Economics & Business
Engineering
Environmental Sciences
Geosciences
Material Science
Mathematics
Medicine
Physics
Social Science
Multidisciplinary
Keywords
(7)
Carbon Nanotube
Charge Transfer
Electrical Resistance
Humidity Sensor
Percolation Threshold
Plasma Treatment
Relative Humidity
Subscribe
Academic
Publications
Novel resistive-type humidity sensor based on multiwall carbon nanotube/polyimide composite films
Novel resistive-type humidity sensor based on multiwall carbon nanotube/polyimide composite films,10.1016/j.snb.2009.11.041,Sensors and Actuators B-ch
Edit
Novel resistive-type humidity sensor based on multiwall carbon nanotube/polyimide composite films
(
Citations: 6
)
BibTex
|
RIS
|
RefWorks
Download
Kum-Pyo Yoo
,
Lee-Taek Lim
,
Nam-Ki Min
,
Myung Jin Lee
,
Chul Jin Lee
,
Chan-Won Park
A novel resistive-type
relative humidity
(RH) sensor based on plasma-treated multiwall carbon nanotube/polyimide (p-MWCNT/PI) composite films is reported. Details of the fabrication process and sensing characteristics such as linearity and sensitivity are described. The
electrical resistance
of the p-MWCNT/PI composite film shows typical concentration percolation behavior with increasing p-MWCNT loading. At loadings beyond the
percolation threshold
(0.05wt%), this sensor exhibits very good linearity with a positive slope over the entire operational RH range. The sensor has a humidity sensitivity of about 0.0047/% RH and a linearity correlation (R2) of 0.9999. A humidity sensing mechanism for the p-MWCNT/PI composite film is proposed on the basis of
charge transfer
between adsorbed water molecules and the p-MWCNTs.
Journal:
Sensors and Actuators B-chemical - SENSOR ACTUATOR B-CHEM
, vol. 145, no. 1, pp. 120-125, 2010
DOI:
10.1016/j.snb.2009.11.041
Cumulative
Annual
View Publication
The following links allow you to view full publications. These links are maintained by other sources not affiliated with Microsoft Academic Search.
(
www.sciencedirect.com
)
(
linkinghub.elsevier.com
)
Citation Context
(2)
...;
Yoo
et al.
, 2009
...
L. Z. Liu
,
et al.
Effects of coupling agents on structure and properties of polyimide/Al...
...The sensitivity of the PIC30 film is at a same level as reported in the reference [
15
], and less sensitive than the pure MWNT network (0.0056%RH) reported in the reference [16]...
...The increase of resistance of CNTs [17, 18] and polymer/CNT [12, 13,
15
] composites due to moisture has been illustrated by former studies, but the mechanism of the increase of resistance is still under discussion...
Qing-Yuan Tang
,
et al.
Fast-response polyimide/multiwall carbon nanotube composite films for ...
References
(26)
A digital hygrometer using a polyimide film relative humidity sensor
(
Citations: 37
)
Hideo Shibata
,
Masahiro Ito
,
Masahiro Asakursa
,
K. Watanabe
Journal:
IEEE Transactions on Instrumentation and Measurement - IEEE TRANS INSTRUM MEAS
, vol. 45, no. 2, pp. 564-569, 1996
Humidity Sensors: A Review of Materials and Mechanisms
(
Citations: 53
)
Zhi Chen
,
Chi Lu
Published in 2005.
A high-speed capacitive humidity sensor with on-chip thermal reset
(
Citations: 55
)
Uksong Kang
,
Kensall D. Wise
Journal:
IEEE Transactions on Electron Devices - IEEE TRANS ELECTRON DEVICES
, vol. 47, no. 4, pp. 702-710, 2000
O2 plasma treated polyimide-based humidity sensors
(
Citations: 6
)
Takeharu Suzuki
,
Philip Tanner
,
David V. Thiel
Journal:
Analyst
, vol. 127, no. 10, pp. 1342-1346, 2002
Fabrication of high-speed polyimide-based humidity sensor using anisotropic and isotropic etching with ICP
(
Citations: 2
)
Jae Sung Kim
,
Myung Jin Lee
,
Moon-Sik Kang
,
Kum-Pyo Yoo
,
Kwang-Ho Kwon
,
V. R. Singh
,
Nam Ki Min
Journal:
Thin Solid Films
, vol. 517, no. 14, pp. 3879-3882, 2009
Sort by:
Citations
(6)
Effects of coupling agents on structure and properties of polyimide/Al2O3 nanocomposite films
L. Z. Liu
,
L. Weng
,
Y. X. Song
,
L. Gao
,
H. Zhao
,
Q. Q. Lei
Journal:
Pigment & Resin Technology - PIGM RESIN TECHNOL
, vol. 40, no. 4, pp. 222-228, 2011
S20 PROLONGED POSTOPERATIVE ILEUS - A RARE, BUT NOT TO UNDERESTIMATE COMPLICATION AFTER RADICAL PROSTATECTOMY
M. Ikic
,
G. Atanassov
,
E. Hauschild
,
C. Guttner
,
X. Krah
Journal:
European Urology Supplements - EUR UROL SUPPL
, vol. 9, no. 6, pp. 563-563, 2010
Fast-response polyimide/multiwall carbon nanotube composite films for monitoring humidity in microelectronic packages
Qing-Yuan Tang
,
Y. C. Chan
Published in 2010.
Sequentially Switched PFN For Inductive And Resistive Loads
(
Citations: 2
)
Adam H. Griffin
,
O. S. F. Zucker
,
D. M. Giorgi
Conference:
Pulsed Power, International Conference - PPC
, 1991
The effect of ALS and ILS localizer on the MLS azimuth phased array antenna
M. Z. El-Gamal
,
S. Latieule
Conference:
Antennas and Propagation Society International Symposium - APSURSI
, 1991