Sign in
Author
|
Conference
|
Journal
|
Organization
|
Year
|
DOI
Look for results that meet for the following criteria:
since
equal to
before
between
and
Search in all fields of study
Limit my searches in the following fields of study
Agriculture Science
Arts & Humanities
Biology
Chemistry
Computer Science
Economics & Business
Engineering
Environmental Sciences
Geosciences
Material Science
Mathematics
Medicine
Physics
Social Science
Multidisciplinary
Keywords
(3)
Nickel
Sterilization
Titanium
Subscribe
Academic
Publications
Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments
Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments,10.1016/S0099-2399(98)80015-0,Journal of Endodontics,Samuel
Edit
Effect of sterilization on cyclic fatigue of rotary nickel-titanium endodontic instruments
(
Citations: 26
)
BibTex
|
RIS
|
RefWorks
Download
Samuel B. Mize
,
David J. Clement
,
John P. Pruett
,
David L. Carnes
Journal:
Journal of Endodontics - J ENDODONT
, vol. 24, no. 12, pp. 843-847, 1998
DOI:
10.1016/S0099-2399(98)80015-0
Cumulative
Annual
View Publication
The following links allow you to view full publications. These links are maintained by other sources not affiliated with Microsoft Academic Search.
(
www.sciencedirect.com
)
(
linkinghub.elsevier.com
)
Citation Context
(2)
...Increased severity in the angle and radius of the curves around which the instrument rotates decreases instrument lifespan (Pruett et al. 1997,
Mize et al. 1998,
Haikel et al. 1999)...
...Two investigations of the causes of instrument fracture in metal-simulated canals have concluded that rotational speed generally is not a significant factor (Pruett et al. 1997,
Mize et al. 1998
)...
...Previous studies using cylindrical metallic tubes to test the cyclic fatigue life of Ni–Ti rotary instruments report that the tubes do not sufficiently constrain the shafts of the smaller instruments (Pruett et al. 1997,
Mize et al. 1998,
Yared et al. 1999, 2000)...
...Cylindrical metallic tubes used in previous studies (Pruett et al. 1997,
Mize et al. 1998,
Yared et al. 1999, 2000, Melo et al. 2002) did not sufficiently restrict the instrument shaft, which would tend to regain its original straight shape, aligning into a trajectory of greater radius and reduced angle (Yared et al. 1999, 2000, Melo et al. 2002, Bahia & Buono 2005)...
...This is the point most widely used in previous cyclic fatigue studies (Pruett et al. 1997,
Mize et al. 1998,
Haikel et al. 1999)...
N. M. Grande
,
et al.
Cyclic fatigue resistance and three-dimensional analysis of instrument...
...Although it has been shown that work hardening (27) or heat treatment(
28
)hasnegligibleinfluenceonthefatigueresistanceofthese instruments, it would be more realistic if the new instruments are also subjectedtosimulatedepisodesofcorrosionstressesasanticipatedfor the used instruments...
Hani F. Ounsi
,
et al.
Effect of Clinical Use on the Cyclic Fatigue Resistance of ProTaper Ni...
References
(3)
The anticurvature filing method to prepare the curved root canal
(
Citations: 38
)
M Abou-rass
,
Al Frank
,
Dh Glick
Published in 1980.
The “balanced force” concept for instrumentation of curved canals
(
Citations: 173
)
J ROANE
,
C SABALA
,
M DUNCANSONJR
Journal:
Journal of Endodontics - J ENDODONT
, vol. 11, no. 5, pp. 203-211, 1985
A comparison of root canal preparations using Ni-Ti hand, Ni-Ti engine-driven, and K-Flex endodontic instruments
(
Citations: 165
)
Charles R. Glosson
,
Robert H. Haller
,
S. Brent Dove
,
Carlos E. del Rio
Journal:
Journal of Endodontics - J ENDODONT
, vol. 21, no. 3, pp. 146-151, 1995
Sort by:
Citations
(26)
Regeneration of natural zeolite polluted by lead and zinc in wastewater treatment systems
(
Citations: 1
)
Evina Katsou
,
Simos Malamis
,
Myrto Tzanoudaki
,
Katherine J. Haralambous
,
Maria Loizidou
Journal:
Journal of Hazardous Materials - J HAZARD MATER
, vol. 189, no. 3, pp. 773-786, 2011
Chemical interferences when using high gradient magnetic separation for phosphate removal: Consequences for lake restoration
I. de Vicente
,
A. Merino-Martos
,
F. Guerrero
,
V. Amores
,
J. de Vicente
Journal:
Journal of Hazardous Materials - J HAZARD MATER
, vol. 192, no. 3, pp. 995-1001, 2011
Cyclic Fatigue Resistance of Rotary Nickel-Titanium Instruments Submitted to Nitrogen Ion Implantation
(
Citations: 1
)
Giulio Gavini
,
Oscar Faciola Pessoa
,
Fernando Branco Barletta
,
M. A. Z. Vasconcellos
,
Celso Luiz Caldeira
Journal:
Journal of Endodontics - J ENDODONT
, vol. 36, no. 7, pp. 1183-1186, 2010
Influence of the shape of artificial canals on the fatigue resistance of NiTi rotary instruments: Influence of trajectory on fatigue resistance
G. Plotino
,
N. M. Grande
,
M. Cordaro
,
L. Testarelli
,
G Gambarini
Journal:
International Endodontic Journal - INT ENDOD J
, vol. 43, no. 1, pp. 69-75, 2010
A Review of Cyclic Fatigue Testing of Nickel-Titanium Rotary Instruments
(
Citations: 13
)
Gianluca Plotino
,
Nicola M. Grande
,
Massimo Cordaro
,
Luca Testarelli
,
Gianluca Gambarini
Journal:
Journal of Endodontics - J ENDODONT
, vol. 35, no. 11, pp. 1469-1476, 2009