Sign in
Author
|
Conference
|
Journal
|
Organization
|
Year
|
DOI
Look for results that meet for the following criteria:
since
equal to
before
between
and
Search in all fields of study
Limit my searches in the following fields of study
Agriculture Science
Arts & Humanities
Biology
Chemistry
Computer Science
Economics & Business
Engineering
Environmental Sciences
Geosciences
Material Science
Mathematics
Medicine
Physics
Social Science
Multidisciplinary
Keywords
(3)
Abdominal Aortic Aneurysm
Endovascular Stent Graft
Polytetrafluoroe...
Subscribe
Academic
Publications
Abdominal Aortic Aneurysm with a Dilated Common Iliac Artery: Treatment Using a Handmade Bifurcated Stent-Graft with a Wide Iliac Limb End
Abdominal Aortic Aneurysm with a Dilated Common Iliac Artery: Treatment Using a Handmade Bifurcated Stent-Graft with a Wide Iliac Limb End,10.1007/s00
Edit
Abdominal Aortic Aneurysm with a Dilated Common Iliac Artery: Treatment Using a Handmade Bifurcated Stent-Graft with a Wide Iliac Limb End
(
Citations: 2
)
BibTex
|
RIS
|
RefWorks
Download
Shiro Miyayama
,
Osamu Matsui
,
Yukari Akakura
,
Toru Yamamoto
,
Hiroto Nishida
,
Kenji Yoneda
,
Keiichi Kawai
,
Shinya Murakami
The purpose of this study was to evaluate the usefulness of a bifurcated stent-graft with a wide iliac limb end (WILE) in the treatment of
abdominal aortic aneurysm
(AAA) with a dilated common iliac artery (CIA) to avoid occlusion of the internal iliac artery (IIA). The WILE, covered with an expanded
polytetrafluoroethylene
graft which was constructed of large diameter stents according to the individual CIA diameter, was connected to a two-piece bifurcated stent-graft covering a polyester graft. The WILE was placed in eight dilated CIAs of six patients. All but one WILE fitted the dilated CIA well. One did not fit, and coil embolization of the leak was needed. All eight IIA derived from the dilated CIA avoided occlusion. Perigraft leak due to other causes was identified in another two patients. Limb kinking was observed in two patients. Our stent is useful in the treatment of AAA with dilated CIA to avoid occlusion of the IIA, and may extend the indication of endoluminal repair of AAA.
Journal:
Cardiovascular and Interventional Radiology - CARDIOVASC INTERVEN RADIOL
, vol. 26, no. 6, pp. 511-515, 2003
DOI:
10.1007/s00270-003-2718-6
Cumulative
Annual
View Publication
The following links allow you to view full publications. These links are maintained by other sources not affiliated with Microsoft Academic Search.
(
www.springerlink.com
)
(
www.springerlink.com
)
(
www.springerlink.com
)
(
www.springerlink.com
)
More »
Citation Context
(1)
...Endovascular repair in patients with AAAs and ectatic common iliac arteries (CIAs) can pose additional technical challenges to the procedure [
2
]...
...Ectatic CIAs may be a risk factor for development of an endoleak from the iliac attachment site of the stent-graft [
2
, 3]. To obtain a seal, the stent-graft can be extended into the external iliac artery (EIA) sacrificing the internal iliac artery (IIA); however, exclusion of the IIA may cause symptoms of buttock claudication, impotence, and bowel necrosis [4, 5] and should be avoided if possible [3]...
Andrew England
,
et al.
Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outco...
References
(7)
Repair of Abdominal Aortic Aneurysm by Transfemoral Endovascular Graft Placement
(
Citations: 92
)
Wesley S. Moore
Journal:
Annals of Surgery - ANN SURG
, vol. 220, no. 3, pp. 331-341, 1994
Clinical experience with a bifurcated endovascular graft for abdominal aortic aneurysm repair
(
Citations: 83
)
Timothy A. M. Chuter
,
Bo Risberg
,
Brian R. Hopkinson
,
George Wendt
,
R. Alan P. Scott
,
Philip J. Walker
,
Salvatore Viscomi
,
Geoffrey White
Journal:
Journal of Vascular Surgery - J VASC SURG
, vol. 24, no. 4, pp. 655-666, 1996
Endoluminal Stent–Grafts for Infrarenal Abdominal Aortic Aneurysms
(
Citations: 251
)
Ulrich Blum
,
Götz Voshage
,
Johannes Lammer
,
Friedhelm Beyersdorf
,
Dierck Töllner
,
Georg Kretschmer
,
Gerhard Spillner
,
Peter Polterauer
,
Gudrun Nagel
,
Thomas Hölzenbein
,
Siegfried Thurnher
,
Mathias Langer
Journal:
New England Journal of Medicine - N ENGL J MED
, vol. 336, no. 1, pp. 13-20, 1997
Internal Iliac Artery Embolization in the Stent-Graft Treatment of Aortoiliac Aneurysms: Analysis of Outcomes and Complications
(
Citations: 58
)
Mahmood K. Razavi
,
Michael DeGroot
,
Cornelius Olcott
,
Daniel Sze
,
Stephen Kee
,
Charles P. Semba
,
Michael D. Dake
Journal:
Journal of Vascular and Interventional Radiology - J VASC INTERVEN RADIOL
, vol. 11, no. 5, pp. 561-566, 2000
Clinical Outcome of Internal Iliac Artery Occlusions during Endovascular Treatment of Aortoiliac Aneurysmal Diseases
(
Citations: 45
)
ChenWei Lee
,
John A. Kaufman
,
Chieh-Min Fan
,
Stuart C. Geller
,
David C. Brewster
,
Richard P. Cambria
,
Glenn M. Lamuraglia
,
Jonathan P. Gertler
,
William M. Abbott
,
Arthur C. Waltman
Journal:
Journal of Vascular and Interventional Radiology - J VASC INTERVEN RADIOL
, vol. 11, no. 5, pp. 567-571, 2000
Sort by:
Citations
(2)
Endovascular Aortic Aneurysm Repair with the Talent Stent-Graft: Outcomes in Patients with Large Iliac Arteries
(
Citations: 8
)
Andrew England
,
John S. Butterfield
,
Charles N. McCollum
,
Raymond J. Ashleigh
Journal:
Cardiovascular and Interventional Radiology - CARDIOVASC INTERVEN RADIOL
, vol. 31, no. 4, pp. 723-727, 2008
Internal Iliac Artery Embolization before Endovascular Repair of Aortoiliac Aneurysms with a Nitinol Vascular Occlusion Plug
(
Citations: 11
)
Ralph Kickuth
,
Florian Dick
,
Jürgen Triller
,
Karin Ludwig
,
Jürg Schmidli
,
Dai-Do Do
Journal:
Journal of Vascular and Interventional Radiology - J VASC INTERVEN RADIOL
, vol. 18, no. 9, pp. 1081-1087, 2007