THE LEKSELL GAMMA KNIFE PERFEXION AND COMPARISONS WITH ITS PREDECESSORS

THE LEKSELL GAMMA KNIFE PERFEXION AND COMPARISONS WITH ITS PREDECESSORS,10.1227/01.neu.0000289726.35330.8a,Neurosurgery,Christer Lindquist,Ian Paddick

THE LEKSELL GAMMA KNIFE PERFEXION AND COMPARISONS WITH ITS PREDECESSORS   (Citations: 17)
BibTex | RIS | RefWorks Download
Journal: Neurosurgery , vol. 61, no. Supplement, pp. 130-141, 2007
Cumulative Annual
View Publication
The following links allow you to view full publications. These links are maintained by other sources not affiliated with Microsoft Academic Search.
    • ...Finally, as an example of further development of SRS, Gamma Knife Perfexion (Elekta Instrument, Stockholm, Sweden) enabled more complex treatment planning by automated collimator arrangement [4]...

    Tomoyuki Kogaet al. Contribution of technological progress, inter-operator difference and ...

    • ...The Leksell Gamma Knife Perfexion (PFX) (Elekta Instruments, Stockholm, Sweden) is a new and entirely redesigned radiosurgery unit, which differs fundamentally from previous models of the Leksell Gamma Knife (Fig. 1). A detailed description of the device has already been published [14, 17, 20]...
    • ...Hybrid shots, i.e., shots that have different collimator values in different sectors, led to new dose planning possibilities [14, 23]...

    Shoji Yomoet al. A quantitative comparison of radiosurgical treatment parameters in ves...

    • ...The care of patients with multiple brain metastases is a fast-growing indication for radiosurgery. Two main problems associated with radiosurgery for these patients have been the relatively long treatment times required to treat each patient and the difficulty of irradiating tumors located at the extreme limits of the brain. In earlier models the stereotactic coordinates were set either manually using trunnions or robotically with an automatic positioning system (APS). APS technology obviated the need to manually adjust each set of coordinates for a multiple-isocenter plan. However, APS had a narrower range in the x (59–141) and y (40–160) dimension. Because of the limitations of the x and y coordinate range of APS, tumors located outside this range needed treatment using the trunnion mode. Thus in a patient with multiple metastases usually some tumors could be treated with APS but others required manual setup for x, y and z coordinates (trunnion mode). The change over form APS to trunnion mode and manual coordinate setup on an average took 10 and 6 min, respectively. This led to longer treatment times for these sick patients. Certain tumors that fell outside the range of the trunnion mode in the x (50–150), y (25–175) or z (40–166) coordinate could not be treated. LGK PFX was designed to address these problems related to the treatment of multiple brain metastases.The Leksell Gamma Knife Perfexion (Elekta Instrument AB, Stockholm, Sweden) (LGK PFX) was introduced in 2006 [...

    Ajay Niranjanet al. Efficiency and Dose Planning Comparisons between the Perfexion and 4C ...

    • ...For more than 20 years, gamma knife radiosurgery has been used successfully in the management of intracranial tumors. Head and neck cancers were eligible for gamma knife radiosurgery only if they invaded the cranial base. The Leksell Gamma Knife® Perfexion™ (Elekta Instruments AB, Stockholm, Sweden) is a new and entirely redesigned radiosurgery technology [...

    Hideyuki Kanoet al. Radiosurgery for Desmoplastic Melanoma of the Head and Neck Using the ...

Sort by: