Sign in
Author
|
Conference
|
Journal
|
Organization
|
Year
|
DOI
Look for results that meet for the following criteria:
since
equal to
before
between
and
Search in all fields of study
Limit my searches in the following fields of study
Agriculture Science
Arts & Humanities
Biology
Chemistry
Computer Science
Economics & Business
Engineering
Environmental Sciences
Geosciences
Material Science
Mathematics
Medicine
Physics
Social Science
Multidisciplinary
Keywords
(9)
Cost Effectiveness
Hiv Testing
Proficiency Testing
Quality Assurance
Quality Control
Resource Limitation
Room Temperature
Sensitivity and Specificity
External Quality Assessment
Subscribe
Academic
Publications
Dried tube specimens: A simple and cost-effective method for preparation of HIV proficiency testing panels and quality control materials for use in resource-limited settings
Dried tube specimens: A simple and cost-effective method for preparation of HIV proficiency testing panels and quality control materials for use in re
Edit
Dried tube specimens: A simple and cost-effective method for preparation of HIV proficiency testing panels and quality control materials for use in resource-limited settings
(
Citations: 2
)
BibTex
|
RIS
|
RefWorks
Download
Bharat S. Parekh
,
Juliana Anyanwu
,
Hetal Patel
,
Marie Downer
,
Mireille Kalou
,
Catherine Gichimu
,
Bera Steven Keipkerich
,
Nelly Clement
,
Michael Omondi
,
Oren Mayer
,
Chin-Yih Ou
,
John N. Nkengasong
HIV testing
has rapidly expanded worldwide, but
proficiency testing
(PT) programs to monitor and improve the quality of testing are often lacking in resource-limited settings (RLS). Traditional PT programs and
quality control
reagents use serum or plasma specimens requiring stringent conditions for storage and transportation.A novel, simple and easy to use approach, based on dried tube specimens (DTS), was developed that can help monitor the quality of HIV antibody testing in RLS. DTS were prepared by drying 20μl of specimen overnight at room temperature. The addition of a green dye (0.1%) made the DTS pellets visible without affecting the test results. Before testing, the DTS were rehydrated with 200μl of PBS–Tween buffer. A panel of 303 DTS samples (135 HIV positive and 168 HIV negative) was evaluated with two rapid tests.
Sensitivity and specificity
with the Determine HIV-1/2 test were 99.3% and 99.4%, respectively, and with OraQuick were 98.5% and 100%, respectively. Stability studies showed that HIV-specific antibodies in the DTS specimens were stable at 4°C and 25°C for 4 weeks, with only marginal decline at 37°C and 45°C over 4 weeks. The DTS-based PT program was piloted successfully in 24 testing sites in Kenya.Results demonstrate that the DTS is a simple to use, practical method to prepare and distribute PT panels and
quality control
specimens to monitor
HIV testing
practices in RLS.
Journal:
Journal of Virological Methods - J VIROL METH
, vol. 163, no. 2, pp. 295-300, 2010
DOI:
10.1016/j.jviromet.2009.10.013
Cumulative
Annual
View Publication
The following links allow you to view full publications. These links are maintained by other sources not affiliated with Microsoft Academic Search.
(
www.sciencedirect.com
)
(
linkinghub.elsevier.com
)
Citation Context
(1)
...For quality assurance, supervisors were provided with proficiency panels prepared by a reference laboratory, consisting of tubes in which sera characterized as positive or negative had been allowed to dry at room temperature. Dried sera were reconstituted with buffered saline on site and used to assess the performance of POCTs by HCWs. This simple, low-cost method was originally developed to assure the quality of HIV testing
...
David C. Mabey
,
et al.
Point-of-Care Tests to Strengthen Health Systems and Save Newborn Live...
References
(12)
Reporting the results of human immunodeficiency virus testing
(
Citations: 5
)
A. S. Benenson
Journal:
Jama-journal of The American Medical Association - JAMA-J AM MED ASSN
, vol. 262, no. 24, pp. 3435-3438, 1989
Evaluation of Thailand national external quality assessment on HIV testing
(
Citations: 3
)
Wilai Chalermchan
,
Sirporn Pitak
,
Suwanee Sungkawasee
Journal:
International Journal of Health Care Quality Assurance
, vol. 20, no. 2, pp. 130-140, 2007
A Quality Assurance Program for Human Immunodeficiency Virus Seropositivity Screening of Dried-Blood Spot Specimens
(
Citations: 7
)
W. Harry Hannon
,
D. Sue Lewis
,
Wanda K. Jones
,
Mary K. Powell
Journal:
Infection Control and Hospital Epidemiology - INFECT CONTROL HOSP EPIDEMIOL
, vol. 10, no. 1, pp. 8-13, 1989
Availability of supplies and motivations for accessing voluntary HIV counseling and testing services in Blantyre, Malawi
(
Citations: 7
)
Bwanali H Jereni
,
Adamson S Muula
Journal:
BMC Health Services Research - BMC HEALTH SERV RES
, vol. 8, no. 1, pp. 17-6, 2008
Development ofQuality Control Procedures fortheHuman Immunodeficiency Virus Type1Antibody Enzyme-Linked Immunosorbent Assay
(
Citations: 1
)
SUE HANAN
,
GARRY L. McKEE
Published in 1989.
Sort by:
Citations
(2)
Point-of-Care Tests to Strengthen Health Systems and Save Newborn Lives: The Case of Syphilis
David C. Mabey
,
Kimberly A. Sollis
,
Helen A. Kelly
,
Adele S. Benzaken
,
Edward Bitarakwate
,
John Changalucha
,
Xiang-Sheng Chen
,
Yue-Ping Yin
,
Patricia J. Garcia
,
Susan Strasser
,
Namwinga Chintu
,
Tikki Pang
http://academic.research.microsoft.com/io.ashx?type=5&id=57417893&selfId1=0&selfId2=0&maxNumber=12&query=
Journal:
PLOS Medicine - PLOS MED
, vol. 9, no. 6, 2012
Recent results an coherent frequency hopping
L. Milstein
Journal:
Infectious Disease Clinics of North America - INFECT DIS CLIN N AMER
, 1989