Sign in
Author
|
Conference
|
Journal
|
Organization
|
Year
|
DOI
Look for results that meet for the following criteria:
since
equal to
before
between
and
Search in all fields of study
Limit my searches in the following fields of study
Agriculture Science
Arts & Humanities
Biology
Chemistry
Computer Science
Economics & Business
Engineering
Environmental Sciences
Geosciences
Material Science
Mathematics
Medicine
Physics
Social Science
Multidisciplinary
Keywords
(8)
High Energy Astrophysics
Monte Carlo Simulation
Particle Tracking
Space Application
X Rays
X-ray Astronomy
X-ray Imaging
Silicon Drift Detector
Subscribe
Academic
Publications
Imaging performance of a large-area Silicon Drift Detector for X-ray astronomy
Imaging performance of a large-area Silicon Drift Detector for X-ray astronomy,10.1016/j.nima.2010.12.237,Nuclear Instruments & Methods in Physics Res
Edit
Imaging performance of a large-area Silicon Drift Detector for X-ray astronomy
(
Citations: 1
)
BibTex
|
RIS
|
RefWorks
Download
R. Campana
,
G. Zampa
,
M. Feroci
,
A. Vacchi
,
V. Bonvicini
,
E. Del Monte
,
Y. Evangelista
,
F. Fuschino
,
C. Labanti
,
M. Marisaldi
,
F. Muleri
,
L. Pacciani
http://academic.research.microsoft.com/io.ashx?type=5&id=49228765&selfId1=0&selfId2=0&maxNumber=12&query=
Large-area multi-anode Silicon Drift Detectors (SDDs) have
X-ray imaging
and spectroscopic characteristics that make them extremely attractive in the perspective of their applications to the field of space astrophysics. We describe here the imaging performance of such a detector, originally developed for
particle tracking
in the ALICE experiment at LHC, as derived by laboratory measurements and
Monte Carlo
simulations. Despite an anode pitch of 294μm, we measured a position resolution as high as ∼20μm by charge weighting in the anode direction, for photon energies in the range 2–10keV. These results are comparable to those obtained with the same detectors in particle tracking. Notwithstanding the 1-D nature of the devices, as far as their read-out is concerned, we envisaged an algorithm that exploits the charge diffusion to reconstruct the position of the photon absorption point also along the drift direction (that is, the one formally not position-sensitive). With the current set-up, the position resolution was measured as ∼3–5mm in the same energy range as above. Such 2-D imaging capability in a 1-D detector, although asymmetric, is highly useful in space applications, where the power and the complexity requested by a 2-D read-out system is sometimes unaffordable.
Journal:
Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment - NUCL INSTRUM METH PHYS RES A
, vol. 633, no. 1, pp. 22-30, 2011
DOI:
10.1016/j.nima.2010.12.237
Cumulative
Annual
View Publication
The following links allow you to view full publications. These links are maintained by other sources not affiliated with Microsoft Academic Search.
(
www.sciencedirect.com
)
(
adsabs.harvard.edu
)
References
(4)
Society for Healthcare Epidemiology of America and Infectious Diseases Society of America Joint Committee on the Prevention of Antimicrobial Resistance: Guidelines for the Prevention of Antimicrobial Resistance in Hospitals
(
Citations: 253
)
David M. Shlaes
,
Dale N. Gerding
,
William A. Craig
,
Donald L. Bornstein
,
Robert A. Duncan
,
Mark R. Eckman
,
William E. Farrer
,
William H. Greene
,
Victor Lorian
,
Stuart Levy
,
Sindy M. Paul
,
Joel Ruskin
http://academic.research.microsoft.com/io.ashx?type=5&id=5255287&selfId1=0&selfId2=0&maxNumber=12&query=
Journal:
Clinical Infectious Diseases - CLIN INFECT DIS
, vol. 25, no. 3, pp. 584-599, 1997
The health professional's role in preventing nosocomial infections
(
Citations: 28
)
H Saloojee
,
A Steenhoff
Journal:
Postgraduate Medical Journal - POSTGRAD MED J
, vol. 77, no. 903, pp. 16-19, 2001
Evaluation of dedicated stethoscopes as a potential source of nosocomial pathogens
(
Citations: 11
)
Cesar H. Guinto
,
Edward J. Bottone
,
John T. Raffalli
,
Marisa A. Montecalvo
,
Gary P. Wormser
Journal:
American Journal of Infection Control - AMER J INFECT CONTROL
, vol. 30, no. 8, pp. 499-502, 2002
Toys in a pediatric hospital: Are they a bacterial source?
(
Citations: 6
)
Marı́a L Avila-Aguero
,
Gabriela German
,
José F Herrera
Journal:
American Journal of Infection Control - AMER J INFECT CONTROL
, vol. 32, no. 5, pp. 287-290, 2004
Sort by:
Citations
(1)
The Large Observatory for X-ray Timing (LOFT)
M. Feroci
,
L. Stella
,
M. van der Klis
,
T. J.-L. Courvoisier
,
M. Hernanz
,
R. Hudec
,
A. Santangelo
,
D. Walton
,
A. Zdziarski
,
D. Barret
,
T. Belloni
,
J. Braga
http://academic.research.microsoft.com/io.ashx?type=5&id=48670016&selfId1=0&selfId2=0&maxNumber=12&query=
Journal:
Experimental Astronomy - EXP ASTRON
, pp. 1-30, 2011