Academic
Publications
Evaluation of longitudinal conversion loss (LCL) for indoor AC mains line

Evaluation of longitudinal conversion loss (LCL) for indoor AC mains line,10.1109/ISEMC.2003.1236705,Simulation Modelling Practice and Theory,A. K. M.

Evaluation of longitudinal conversion loss (LCL) for indoor AC mains line   (Citations: 8)
BibTex | RIS | RefWorks Download
Influence to electromagnetic environment has been studied for power line communication (PLC). Longitudinal conversion loss (LCL) and input impedance are important parameters to evaluate the influence. Indoor AC mains line is modeled considering with typical conditions of Japanese house. The modeled line and electric equipment are presented with 4-port F-matrixes. The parameters of 4-port F-matrix are determined from calculation and measurement. Using this model, the input impedance and the LCL are calculated. The analysis model is examined by a simple network, and the results show that the calculation values almost agree with the measured values. The input impedance and the LCL are investigated for actual AC mains line, and the measured results almost agree with the calculated value.
Cumulative Annual
View Publication
The following links allow you to view full publications. These links are maintained by other sources not affiliated with Microsoft Academic Search.
    • ...Since at large distance from the wires, the radiation is mainly due to the common mode current, extensive analyses have been published in the literature on the differential mode (DM) to common mode (CM) current conversion mechanism, due to network imbalance, and on the longitudinal conversion loss defined as the ratio of these two currents [1], [2]...

    Pierre Degauqueet al. Compromising Electromagnetic Field Radiated by In-House PLC Lines

    • ...Hence, the radiation from power-line cables, the mitigation of such radiation, and the influence of longitudinal conversion loss (LCL) have been studied [3], [4], [5], and [6]...

    Kazuhiro Takayaet al. Experimental evaluation of the induced current by the PLC leakage elec...

    • ...In the examinations using four port network theory used in this paper, many papers exist, such as papers; LCTL (Longitudinal Conversion Transmission Loss) and leaked electric field of a balanced pair cable have been calculated [3-5], LCTL of PCB (Printed Circuit Board) [6], and LCL and transmission characteristics of power line [7][8] have been examined, and then induction characteristics between power line and other communication line has ...

    J. Karinoet al. LCL Characteristics of Power Line for Power Line Communication Using F...

    • ...The quantification of leaked electric field of which the index is the degree of unbalance about earth such as LCL (Longitudinal Conversion Loss) is one of them [3][4][5]...

    Yousuke WATANABEet al. Influence of ground plane to distance dependence leaked electric field...

    • ...Therefore, there have been many studies of electromagnetic field radiating from AC mains line [1], [2], longitudinal conversion loss (LCL) for indoor AC mains line [3], radiation reduction in PLC system using a hybrid feeding [4], and the effect of PLC signals on VDSL systems [5]...
    • ...Analyses of the radiated field [2], input impedance [3], and LCL [3] have been presented...
    • ...Analyses of the radiated field [2], input impedance [3], and LCL [3] have been presented...
    • ...The input impedance and the LCL can be calculated according with the method presented in reference [3]...
    • ...The common-mode input impedance and the LCL were obtained by the method given in the reference [3]...
    • ...The indoor AC mains line model investigated in this section is shown in Fig. 14. The model presents one sub-branch of the AC mains line for a small house [3]...
    • ...In this experiment, artificial equipment, which was obtained from the equivalent circuit of the appliances [3] was used...
    • ...The four-port networks representing appliances and AMN were obtained from the equivalent circuit using the similar method given in the reference [3]...
    • ...The simple model shown in Fig. 1 was obtained for each branch using a matrix conversion technique [3], and the common-mode current in each segment was calculated using the method presented in this paper...

    Kingo Miyoshiet al. Calculation of radiating magnetic field from indoor AC mains cable usi...